Viking LDB-3 Specifiche Pagina 3

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 4
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 2
S1
1
2
ON
3
11
10
9
8
7
6
5
4
3
2
1
* Gel-Filled Butt
Connectors (included)
Note: Polarity Sensitive!
(-) Black with
White stripe
120V AC
(+) Red with
Black stripe
(+) Black
* Gel-Filled Butt
Connectors
(included)
Red (+)
Red (+)
Black (-)Black (-)
Rear View of the
Strobe Light (included)
Red with
Yellow stripe
Green with
Yellow stripe
Brown
Gray
LDB-3 Control Module
(included)
Auxiliary
Contact Output
Blue
Blue
Incoming
Analog
Phone Line
Phone or
Terminal Device
(not included)
Disable Feature (see
Programming section F)
Purple
Orange
Yellow
N.C.
COM.
N.O.
12V DC
Adapter
Included
(-) Black with
White stripe
2.75”
(2) #8-32 x 2 1/2 Phillips
Head Self Tapping Screws (included)
(2) #10-32 x 5/8
Phillips Head Self
Tapping Screws
(included)
Strobe Light
(included)
B. Front Mounting Without Weatherproof Box
The BLK-3-EWP Strobe Light Kit may be mounted with-
out using the included weatherproof box. To mount the
strobe light from the front, use the diagram below.
To mount the strobe light from the rear, use the
diagram below.
C. Rear Mounting Without Weatherproof Box
P
P
r
r
o
o
g
g
r
r
a
a
m
m
m
m
i
i
n
n
g
g
Strobe Light
(included)
Wall, post, etc.
2. Loop/Off-hook Indication Only
The LDB-3 control module must be placed between the phone line and the phone/terminal device to be monitored. Connect the
incoming line to the red and green wires with the yellow stripe and connect the phone/terminal device to the brown and gray
wires as shown.
3. Both Ring and Loop/Off-hook Indication
If the application requires ring and loop/off-hook indication, the LDB-3 control module must be placed between the phone line
and the phone/terminal device to be monitored. Connect the incoming line to the red and green wires with the yellow stripe, con-
nect the phone/terminal device to the brown and gray wires.
1. Ring Indication Only
Connect the incoming line to the red and green wires with the yellow stripe as shown in the diagram. No phone/terminal device
is required. The LDB-3 control module can monitor for ringing any place along the ringing line.
B. Configuring for Ring and/or Loop/Off-Hook Indication
A. DIP Switches
Sw 1
ON
OFF
ON
Sw 3
OFF
ON
ON
Description
Ring Detection Only (see section B).
Off-Hook/Loop Current Detection Only (see section B).
Ring and Off-Hook/Loop Current Detection (see section B).
Sw 2
ON
OFF
Ring Cadence Mode (see section C)
Ring Cadence Mode ON - relay remains activated in between rings.
Ring Cadence Mode OFF - relay is activated only during ringing.
Red
Black
To LDB-3
Control
Module
(included)
Red
Black
To LDB-3
Control
Module
(included)
S1
1
2
ON
3
11
10
9
8
7
6
5
4
3
2
1
1
2
3
ON
* Note: The gel-filled (water tight) butt connectors
are designed for insulation displacement. Do not
strip wires prior to terminating.
Note: The phone and
incoming line connec-
tions are NOT polarity
sensitive.
C. Ring Cadence Mode
DIP switch 2 is used for switching between different ring detection modes. In the OFF position, the relay and switched 12VDC out-
put will activate only while ring voltage is present and will turn off between rings. In the ON position, the relay and switched 12VDC
output will remain on for up to 5.75 seconds after the ringing has stopped. This allows the relay and 12VDC (flashing strobe light)
to remain on between rings of a standard ring cadence. Note: To use the Ring Cadence Mode, ring detection MUST be enabled
(DIP switch 1 - ON).